PDU 400V, 3P, 32A, 24 Outlets
search
  • PDU 400V, 3P, 32A, 24 Outlets
  • PDU
  • PDU
PDU 400V, 3P, 32A, 24 Outlets
PDU 400V, 3P, 32A, 24 Outlets PDU PDU

PDU

€2,550.00
Tax excluded

PDU 400V, 3P, 32A, 24 Outlets: 12 x Locking C13, 12 x Locking Cx, Input: IEC 60309 3P+N+E 32A, 0U, 22.1kW

Quantity

400V,3P, 32A, 24 Outlets: 12 x Locking HDOT C13, 12 x Locking Cx, Input: IEC 60309 3P+N+E 32A, 0U, 22.1kW, 6 x 16A (1-pole) 10kAIC breaker, Outlet Metered/Switched, Alt-Branch, iX Controller.

60C;10kAIC Breakers;Branch Current Monitoring

 

Energy Metering: Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy: Class 0.5 meter

Metering per input line: Yes

Metering per Branch Circuit Breaker: Yes

Metering per Output Receptacle: Yes

Remote Outlet Switching: Yes

Power Quality Monitoring: Voltage and Current Harmonic Distortion; Distortion Power Factor; Voltage Dip and Voltage Swell; Neutral Current, Current Inrush, Crest Factor

Outlet Power Distribution: Alternating Branch

Replaceable Controller: Yes, hot-swappable

Environmental Sensor Ready: Yes

Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Dust/Particle, Water Leak, Proximity/Motion, Vibration, Dry Contact, and Contact Closure.

PDU Linking: Link up to 8 PDUs where the Primary PDU has knowledge and power information from the attached Expansion PDUs. Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.

Cascading: Physically cascade 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode, or additionally, save IP addresses using a single IP address with port forwarding.

Linking: Yes, a maximum of 8 PDUs can be linked using the PDU Link Port; PDU 1 is defined as the Primary PDU and can link up to 7 additional PDUs, called Link PDUs, totaling 8 PDUs.

Networking: (10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet. Optional WiFi (802.11 a/b/g/n).

Remote Management: HTTP(s); SSH (CLI); Telnet; RS-232 (Serial); SNMP version v2/v3; SMTP; JSON-RPC API; MODBUS-TCP; Redfish API

Onboard Display: Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation.

Raritan
PX4-5917-E7V2

Data sheet

Phase
3
Volt
400
Ampère
32
Number of outlets
24
Type outlets
C13, Cx
kVA
22.1
Type
Outlet Metered and Switched
Form
0U
Cord length
3
Dimensions
56mm x 65mm x 1539mm