PDU 3PH, 400V AC, 16A, 16A,/PH, rated 36 outlets 24x C13 12x
search
  • PDU 3PH, 400V AC, 16A, 16A,/PH, rated 36 outlets 24x C13 12x
PDU 3PH, 400V AC, 16A, 16A,/PH, rated 36 outlets 24x C13 12x

PDU 3PH, 400V AC, 16A, 16A,/PH, rated 36 outlets 24x C13 12x C19, 11.1kVA Unit Metered, Zero U vertical

€1,013.00
Tax excluded

3PH, 400V AC, 16A (16A/PH rated); 36 outlets: 24x C13, 12x C19; plug: IEC 60309 3P+N+E 6h 16A (Wye Bottom-front feed), 11.1kVA; Unit Metered, Zero U vertical PDU, SecureLock ready, high resolution color display with field replaceable controller, Ethernet, serial, 2x USB-A, USB-B and sensor connections

Quantity

Monitored rack power distribution unit (0U [vertical], 11.1kVA, 36 outlets).

INPUT: 400v (3-phase WYE), 16a - IEC 60309 3P+N+E 6h 16A plug (4P5W);

OUTPUT: 24x C13, 12x C19 outlets; 

Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet;

Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3.

Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM.

Cascading upto 16 PDU's using single Ethernet or USB connection.

Environmental monitoring [temp/humidity] capable – up to 32 sensors.

Individual outlet numbers labeled on chassis.

Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives.

WiFi Capable.

USB Webcam Capable.

iPad/iPhone/Android App.

Dual 10/100/1000 Ethernet port.

Max Dimensions 52mm x 43mm x 1780mm (2.1in x 1.7in x 70.1in).

Max Weight 5.6 kg.

Maximum ambient temperature 60C at full load.

Features

Energy Metering: Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy: ISO/IEC 62053-21 1%

Remote Outlet Switching: No

Metering per input line: Yes

Metering per Branch Circuit Breaker: No

Environmental Sensor Ready: Yes

Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.

PDU Linking: Link up to 8 PDUs where the Primary PDU has knowledge and power information from the attached Expansion PDUs. Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.

Cascading: Physically cascade 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode, or additionally, save IP addresses using a single IP address with port forwarding.

Networking: (10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet. Optional WiFi (802.11 a/b/g/n).

Onboard Display: Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation

 

Raritan
PX3-1732

Data sheet

Phase
3
Volt
400
Ampère
16
Number of outlets
36
Type outlets
C13, C19
Inlet plug
IEC 60309
kVA
11.1
Type
Unit Metered
Form
0U
Cord length
3
Dimensions
52mm x 43mm x 1780mm