PDU 3PH, 400V AC, 32A, 18x C13 6x C19, 22.
search
  • PDU 3PH, 400V AC, 32A, 18x C13 6x C19, 22.
PDU 3PH, 400V AC, 32A, 18x C13 6x C19, 22.

PDU 3PH, 400V AC, 32A, 18x C13 6x C19, 22.2kVA Outlet Metered and Switched, Zero U vertical

€ 2.404,00
Exclusief belasting

3PH, 400V AC, 32A (32A/PH rated); 24 outlets: 18x C13, 6x C19; plug: IEC 60309 3P+N+E 6h 32A (Wye Bottom-bottom feed), 22.2kVA; Outlet Metered/Switched, Zero U vertical PDU, SecureLock ready, V2 Outlet Sequence, high resolution color display with field replaceable controller, Ethernet, serial, 2x USB-A, USB-B and sensor connections

Aantal

Monitored and switched rack power distribution unit (0U [vertical], 22.2kVA, 24 outlets).

INPUT: 400v (3-phase WYE), 32a - IEC 60309 3P+N+E 6h 32A plug (4P5W);

OUTPUT: 18x C13, 6x C19 outlets; on 6x 1-pole, 16a Overcurrent Protectors;

FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet;

Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3.

Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM.

Cascading upto 16 PDU's using single Ethernet or USB connection.

Environmental monitoring [temp/humidity] capable – up to 32 sensors.

Individual outlet numbers labeled on chassis.

Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives.

WiFi Capable. USB Webcam Capable.

iPad/iPhone/Android App.

Dual 10/100/1000 Ethernet port.

Tri-color status LED per receptacle.

Breaker metering and alarming (0V detection).

Max Dimensions 52mm x 65mm x 1780mm (2.1in x 2.6in x 70.1in).

Max Weight TBD.

Maximum ambient temperature 60C at full load.

Kenmerken

Energy Metering: Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy: ISO/IEC 62053-21 1%

Remote Outlet Switching: Yes

Metering per input line: Yes

Metering per Branch Circuit Breaker: No

Environmental Sensor Ready: Yes

Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.

PDU Linking: Link up to 8 PDUs where the Primary PDU has knowledge and power information from the attached Expansion PDUs. Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.

Cascading: Physically cascade 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode, or additionally, save IP addresses using a single IP address with port forwarding.

Networking: (10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet. Optional WiFi (802.11 a/b/g/n).

Onboard Display: Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation

Raritan
PX3-5528V-V2

Datasheet

Phase
3
Volt
400
Ampère
32
Number of outlets
24
Type outlets
C13, C19
Inlet plug
IEC 60309
kVA
22.2
Type
Outlet Metered and Switched
Form
0U
Cord length
3
Dimensions
52mm x 65mm x 1780mm